3.2 LTE and RADEX Analysis


Contents
  1. Utility of the LTE and RADEX analysis tool
  2. How does it work?

3.2.1 Utility of the LTE and RADEX analysis tool

CASSIS can model astronomical spectra using plugged-in models. Presently a Local Thermodynamic Equilibrium model (described here) and a statistical equilibrium radiative transfer code, RADEX, (described here), using the Leiden Atomic and Molecular Database (described here), are available. RADEX is a one-dimensional non-LTE radiative transfer code, that uses the escape probability formulation assuming an isothermal and homogeneous medium without large-scale velocity fields. RADEX is comparable to the LVG method (see our LVG documentation) and provides a useful tool in rapidly analyzing a large set of observational data providing constraints on physical conditions, such as density and kinetic temperature.

3.2.2 How does it work?

Click on the third menu, Models, and choose LTE + RADEX. Alternatively, click on the icon . In both cases, a pop-up window opens:

If you want to model a source, you need to specify the following parameters:

  1. Tuning panel:
    1. If you want a specific frequency range, select the Range [GHz] button and enter the minimum and maximum frequencies in GHz.
    2. If you want to center on a specific line, select the Line [GHz] button and enter the line frequency in GHz.
      NOTE: make sure you hit 'enter' after typing the line frequency value, in order to automatically update the frequency of the local oscillator (LO freq. [GHz] field), depending on the telescope you choose ; the later is done by clicking on the telescope name, which brings up a file browser.
      If you want to model a spectrum in DSB mode, select the DSB button and choose in the pull-down menu the tuning band (LSB or USB) you want to use.
      Additionally, you can set the bandwidth in GHz.
    3. In both cases, you can set the spectral resolution in the dv [MHz] box.
      WARNING: a high spectral resolution combined with a broad spectral range yields a large number of points and hence increases the computing time and can lead to a memory overflow.

  2. Threshold panel:
    You can select a (lower and/or upper) limit on the upper energy (Eup) of the lines you request, as well as the minimum Einstein coefficient (Aij min) and other quantum numbers. This will lower the calculation time.

  3. Parameters panel:
    1. If tuning on a specific line, the telescope is automatically set to be the same as in the "Tuning" panel. If tuning over a frequency range, set the desired Telescope by clicking on the telescope name, which brings up a file browser from which you can choose the desired telescope file. If the telescope you want does not exist, you can add it simply by duplicating one of the telescope files in YOUR_CASSIS_DIRECTORY/delivery/telescope/ and changing the parameters to match those of the desired telescope.
      WARNING: Take care that you do not change the format of the file !
    2. By default, CASSIS computes the spectrum in Tmb; however, if you want the modeled spectrum in Ta units, select the Tmb->Ta conv box.

  4. In the Noise panel, you can add a white noise by modifying the rms in milli-Kelvin.

  5. The Frequency scale panel allows you to choose between "Rest frequency" or "Sky frequency of the 1st component" for your model.

  6. The last panel concerns the source parameters. You can model as many lines as you want. Depending on the line parameters you defined, the modeled spectrum will be in absorption or in emission (see this document for more details).

    In the Mode pull-down menu, you can choose whether you want to model your lines in LTE only (Full LTE) or RADEX only (Full RADEX).
    WARNING: choosing "Full RADEX" will only produce a model which includes lines that are tabulated in the LAMDA database.

    On the right-hand side some parameters are listed: In the Molecules pull-down menu, you can select the template you want to use (Full CDMS, Full JPL, Full VASTEL to get the ortho and para separation for some molecules, Full NIST, CO CDMS as a simple example, Full DATABASE to get everything).
    You can also create your own template (see Section 4). All the species in the selected template appear in the lower part of the window:
    1. Species: name of the species found in the database (the name might be slightly different between JPL and CDMS for the same species).
    2. Tag: this tag is used to identifiy the species as well as the database (the antepenultimate digit of the tag is representative of the database: 0 for JPL; 1 for NIST, 5 for CDMS). Click on Tag to sort the values.
    3. Database: name of the database.
    4. Collision: corresponds to the collision coefficient. Listed as "-no-" means that there are no collision coefficient available (yet) for the species. When the collision coefficients are available, if you decide to use RADEX, you must select a collision partner as well as its number density. For that click on the collision file in the Collision column (for example co.dat in the case of CO/CDMS). A pop-up window opens and you can modify the partners densities and save your changes.
    5. Compute: select the species that you want to model. You can select/de-select all species by clicking on Compute.
    6. N(Sp) (/cm2): Column density of the species in cm-2. Mandatory for both LTE and RADEX models.
    7. Abundance: abundance relative to H2.
    8. Tex (K): excitation temperature. Mandatory for LTE modeling. Not used for RADEX as it is an output.
    9. Tkin (K): kinetic temperature. Mandatory for RADEX. Not used for the LTE model.
    10. FWHM [km/s]: Intrinsic Full Width at Half Maximum of the lines (in km/s) before broadening from the line optical depth.
    11. Size (''): Source size in arcsec to take into account the beam dilution, which is computed as:
      Θ2source/(Θ2source+Θ2beam).
      If you want to model a source independantly of a telescope you can simply use a extremely large source size.
    NOTES:

  7. You can add as many components (sources) as you want using the "plus" tab. You can also move or copy any component by right-clicking on it.

Finally, to display the modeled spectrum, click on the Display button. For the parameters in Figure 1, you will obtain the following: